The system/ directory holds one registry file for each entity type. This page documents the six registries other than the hydro plants: buses, lines, thermal plants, non-controllable sources, pumping stations and energy contracts. system/buses.json is required; the other five files are optional, and an absent one means the study has no entity of that type. The hydro plant registry is on Hydro Plant Files. Every entity carries a required operational_start_date, described once under Shared entity fields.


Methodology: System Element Modeling Overview

Electrical bus registry. Buses are the nodes of the transmission network.

NameTypeRequiredDefaultUnitsDescription
buses[].idintegerYes——Bus identifier (integer, unique)
buses[].namestringYes——Human-readable bus name (string)
buses[].operational_start_datestringYes——Required on every entity; see Shared entity fields.
buses[].deficit_segmentsarray | nullNo——Entity-level deficit cost tiers; when present they replace bus.deficit_segments in penalties.json for this bus and follow the same rules (non-empty, costs strictly increasing, last depth_mw null)
buses[].deficit_segments[].depth_mwnumber | nullNo—MWSegment depth (MW); the last segment’s depth_mw must be null (unbounded)
buses[].deficit_segments[].costnumberYes—USD/MWhCost per MWh of deficit in this tier (USD/MWh); > 0

Methodology: System Element Modeling Overview · Equipment-Specific Formulations

Transmission line registry. Lines connect buses and carry power flows. The file is optional; when absent, no lines are modeled.

NameTypeRequiredDefaultUnitsDescription
lines[].idintegerYes——Line identifier (integer, unique)
lines[].namestringYes——Human-readable line name (string)
lines[].source_bus_idintegerYes——Sending-end bus ID
lines[].target_bus_idintegerYes——Receiving-end bus ID
lines[].operational_start_datestringYes——Required on every entity; see Shared entity fields.
lines[].entry_stage_idinteger | nullNonull—Stage when line enters service; null = always exists
lines[].exit_stage_idinteger | nullNonull—Stage when line is decommissioned; null = never
lines[].capacity.direct_mwnumberYes—MWMaximum power flow in the direct direction (MW)
lines[].capacity.reverse_mwnumberYes—MWMaximum power flow in the reverse direction (MW)
lines[].exchange_costnumber | nullNonullUSD/MWhEntity-level exchange cost override (USD/MWh); absent = line.exchange_cost in penalties.json
lines[].losses_percentnumberNo0.0%Transmission losses as percentage (default: 0.0)

Validation:

  • entry_stage_id must be less than exit_stage_id when both are set.
  • capacity.direct_mw, capacity.reverse_mw and losses_percent must be >= 0.

Methodology: Equipment-Specific Formulations · State Augmentation

Thermal plant registry. Each entry defines a dispatchable generation unit. The file is optional; when absent, no thermal plants are modeled.

NameTypeRequiredDefaultUnitsDescription
thermals[].idintegerYes——Plant identifier (integer, unique)
thermals[].namestringYes——Human-readable plant name
thermals[].bus_idintegerYes——Bus where generation is injected
thermals[].generationobjectYes——Dispatch-bounds object with min_mw and max_mw
thermals[].generation.min_mwnumberYes—MWMinimum dispatch level (MW)
thermals[].generation.max_mwnumberYes—MWMaximum dispatch level (MW)
thermals[].cost_per_mwhnumberYes—USD/MWhLinear generation cost (USD/MWh)
thermals[].operational_start_datestringYes——Required on every entity; see Shared entity fields.
thermals[].entry_stage_idinteger | nullNonull—Stage when the unit enters service (null = present from stage 0)
thermals[].exit_stage_idinteger | nullNonull—Stage when the unit is decommissioned (null = never)
thermals[].anticipated_configobject | nullNo——Anticipated-dispatch lead: an object with exactly one of lead_stages (integer >= 1) or lead_time_hours (finite and > 0); both or neither is rejected at load. See the Equipment-Specific Formulations Configure tab
thermals[].anticipated_config.lead_stagesintegerConditional——Anticipated-dispatch lead in stages (integer >= 1). Exactly one of lead_stages or lead_time_hours is set; both or neither is rejected at load.
thermals[].anticipated_config.lead_time_hoursnumberConditional—hAnticipated-dispatch lead in hours (finite and > 0). Exactly one of lead_stages or lead_time_hours is set; both or neither is rejected at load.

Validation:

  • entry_stage_id must be less than exit_stage_id when both are set.
  • generation.min_mw and generation.max_mw must be >= 0, with max_mw >= min_mw; cost_per_mwh must be >= 0.

Methodology: Equipment-Specific Formulations

Non-controllable source (NCS) registry. Each entry defines an intermittent or aggregate generator — wind, solar, small hydro, biomass, distributed generation — whose available output is a scenario input rather than a free LP decision. The file is optional; when absent, no non-controllable sources are modeled. Per-scenario availability is supplied by the scenarios/non_controllable_factors.json and scenarios/non_controllable_stats.parquet inputs.

NameTypeRequiredDefaultUnitsDescription
non_controllable_sources[].idintegerYes——Source identifier (integer, unique within the file)
non_controllable_sources[].namestringYes——Human-readable source name (string)
non_controllable_sources[].bus_idintegerYes——Bus into which the source’s generation is injected
non_controllable_sources[].operational_start_datestringYes——Required on every entity; see Shared entity fields.
non_controllable_sources[].max_generation_mwnumberYes—MWInstalled capacity [MW]; it scales the stochastic availability and does not cap the available generation
non_controllable_sources[].allow_curtailmentbooleanNotrue—Whether the LP may curtail this source. true (default) — dispatch within [0, max_generation_mw × availability] at the curtailment cost; false — must-run, dispatch pinned to the realized availability every scenario
non_controllable_sources[].curtailment_costnumber | nullNonullUSD/MWhEntity-level curtailment cost override [USD/MWh]; falls back to non_controllable_source.curtailment_cost in penalties.json when absent
non_controllable_sources[].entry_stage_idinteger | nullNonull—Stage when the source enters service; null or absent = present from stage 0
non_controllable_sources[].exit_stage_idinteger | nullNonull—Stage when the source is decommissioned; null or absent = never

Minimal valid example:

{
"$schema": "https://docs.modelossetoreletrico.org.br/schemas/non_controllable_sources.schema.json",
"non_controllable_sources": [
{
"id": 0,
"name": "Complexo Eólico Nordeste",
"bus_id": 4,
"operational_start_date": "2015-06-01",
"max_generation_mw": 1200.0
}
]
}

Validation:

  • entry_stage_id must be less than exit_stage_id when both are set.
  • max_generation_mw must be >= 0.

Methodology: Equipment-Specific Formulations

Pumping station registry. Each entry defines a pumped-storage or water-transfer installation that withdraws water from a source hydro reservoir, injects it into a destination hydro reservoir, and consumes electrical power from a bus. The file is optional; when absent, no pumping stations are modeled.

NameTypeRequiredDefaultUnitsDescription
pumping_stations[].idintegerYes——Station identifier (integer, unique)
pumping_stations[].namestringYes——Human-readable station name (string)
pumping_stations[].bus_idintegerYes——Bus from which electrical power is consumed
pumping_stations[].source_hydro_idintegerYes——Hydro plant from whose reservoir water is extracted
pumping_stations[].destination_hydro_idintegerYes——Hydro plant into whose reservoir water is injected
pumping_stations[].consumption_mw_per_m3snumberYes—MW/(m³/s)Power drawn per unit of pumped flow [MW/(m³/s)]; must be >= 0
pumping_stations[].operational_start_datestringYes——Required on every entity; see Shared entity fields.
pumping_stations[].entry_stage_idinteger | nullNonull—Stage when the station enters service; null or absent = present from stage 0
pumping_stations[].exit_stage_idinteger | nullNonull—Stage when the station is decommissioned; null or absent = never
pumping_stations[].flowobjectYes——Nested object with min_m3s and max_m3s (see below)
pumping_stations[].flow.min_m3snumberYes—m³/sMinimum pumped flow [m³/s]; must be >= 0
pumping_stations[].flow.max_m3snumberYes—m³/sMaximum pumped flow (installed pump capacity) [m³/s]; must be >= flow.min_m3s

The pumped flow variable is bounded by [flow.min_m3s, flow.max_m3s] in the LP. At each stage within [entry_stage_id, exit_stage_id), the flow appears with a negative sign in the source reservoir water-balance row and a positive sign in the destination reservoir water-balance row. Power consumed equals consumption_mw_per_m3s × flow_m3s and is charged as load on the station’s bus. Stage-varying flow bounds can be overridden via constraints/pumping_bounds.parquet.

Minimal valid example:

{
"$schema": "https://docs.modelossetoreletrico.org.br/schemas/pumping_stations.schema.json",
"pumping_stations": [
{
"id": 0,
"name": "Bombeamento Serra da Mesa",
"bus_id": 10,
"operational_start_date": "2010-09-15",
"source_hydro_id": 3,
"destination_hydro_id": 5,
"consumption_mw_per_m3s": 0.5,
"flow": { "min_m3s": 0.0, "max_m3s": 150.0 }
}
]
}

Validation:

  • entry_stage_id must be less than exit_stage_id when both are set.
  • source_hydro_id must differ from destination_hydro_id.
  • The station is in service only at stages where both its source and its destination hydro are Operating (neither PreFilling nor Filling); see Equipment-Specific Formulations for the rule.

Methodology: Equipment-Specific Formulations

Energy contract registry. Each entry defines a bilateral energy purchase or sale obligation with a counterparty outside the modeled system. The file is optional; when absent, no contracts are modeled.

NameTypeRequiredDefaultUnitsDescription
contracts[].idintegerYes——Contract identifier (integer, unique)
contracts[].namestringYes——Human-readable contract name (string)
contracts[].bus_idintegerYes——Bus where power is injected (import) or withdrawn (export)
contracts[].typestringYes——One of "import", "export". Energy flow direction.
contracts[].price_per_mwhnumberYes—USD/MWhContract price [USD/MWh]. Positive = cost (import); negative = revenue (export)
contracts[].limits.min_mwnumberYes—MWMinimum dispatch level [MW]; use 0.0 unless a take-or-pay floor applies
contracts[].limits.max_mwnumberYes—MWMaximum dispatch level [MW]; must be >= limits.min_mw
contracts[].operational_start_datestringYes——Required on every entity; see Shared entity fields.
contracts[].entry_stage_idinteger | nullNonull—Stage when the contract enters service; null or absent = present from stage 0
contracts[].exit_stage_idinteger | nullNonull—Stage when the contract is decommissioned; null or absent = never

At each active stage within [entry_stage_id, exit_stage_id), the LP adds one column per block per direction bounded by [limits.min_mw, limits.max_mw]. An import column injects +1.0 MW into the bus power-balance row; an export column withdraws −1.0 MW. At dormant stages the column bounds are pinned to [0, 0] and the output row is emitted with power_mw = 0. Stage-varying bounds and prices can be overridden via constraints/contract_bounds.parquet.

Minimal valid example:

{
"$schema": "https://docs.modelossetoreletrico.org.br/schemas/energy_contracts.schema.json",
"contracts": [
{
"id": 0,
"name": "Import base load",
"bus_id": 0,
"operational_start_date": "2018-01-01",
"type": "import",
"price_per_mwh": 200.0,
"limits": { "min_mw": 0.0, "max_mw": 50.0 }
},
{
"id": 1,
"name": "Export revenue (stage 1 only)",
"bus_id": 0,
"operational_start_date": "2019-06-01",
"type": "export",
"entry_stage_id": 1,
"exit_stage_id": 2,
"price_per_mwh": -150.0,
"limits": { "min_mw": 0.0, "max_mw": 30.0 }
}
]
}

Validation:

  • entry_stage_id must be less than exit_stage_id when both are set.
  • limits.min_mw and limits.max_mw must be >= 0.