Skip to content

Load

Load is the electrical power consumed at a bus. It is the demand that the load balance of that bus must meet in every block, and it can vary from block to block through a load-factor table.

What the system must serve

In each block, the generation, imports and power arriving over lines at a bus, plus the deficit, less exports, pumping consumption, power leaving over lines and excess, must equal its load.

Varies by block

A stage load is turned into the load of each block by a per-block factor. Brazilian practice names the three load blocks leve, média and pesada (light, medium, heavy).

Uncertain by stage

Load is described by a mean and a standard deviation for each bus and stage, and each scenario draws its own realization.

The stage load, adjusted by the factor of each block load at the bus (MW) leve (light) média (medium) pesada (heavy) stage load (factor 1) Each bar is the stage load times the block factor.
Figure: the load of a bus per load block. Illustrative values, not to scale.

Nothing about the load itself: it is data, not a decision. What the model decides is how to meet it, with the generation, imports and line flows available, and with deficit as the last resort (see the Deficit page).

  • For each bus and stage, the mean load and its standard deviation, in MW. A standard deviation of zero makes the load deterministic.
  • Optionally, load factors for each bus, stage and block, which must be positive. A block with no factor carries the stage load unchanged, and without the factor file every factor is 1.
  • Optionally, pre-computed load scenarios, when the load comes from an external source.
  • Optionally, correlation between the loads of different buses, through correlation groups.
  • Without load statistics, every bus carries zero load, unless the load scheme is external in training.
  • With load statistics, each scenario draws a realization for each bus and stage from the mean plus the standard deviation times a random noise, and the result is never negative: it is truncated at zero. Load has no autoregressive structure.
  • By block, the load realization of the stage is multiplied by the block factor of the bus.

The simulation output reports, for each bus and block, the load in MW and the load energy over the block in MWh, next to the deficit, the excess and the spot price.